16 Nisan 2013 Salı

Hantek MSO5062D 60 Mhz Dijital Osiloskop + 16 Kanal Lojik Analizör

www.emfaelektronik.com.tr
www.osiloskops.com


Name MSO5000D Series Mixed Signal Digital Oscilloscope
SC 16 logical channels (divided into 2 groups)+2 analog channels + external trigger channel; 1M memory depth; 1GSa/s real time sampling rate; 7 inch TFT color display (800 x 480); powerful trigger function.
Full
1. Download
【Software】 【Driver】 【Manual】
2.Accessories






 3.Other Pictures















 4. Feature
l          16 channels logic analyzer + 2 channels oscilloscope + external trigger.
l          Big and clear display (7.0-inch color LCD, high revolution 800 x 480), clear lifelike waveform display.
l          1GSa/s real time sampling rate.
l          60MHz-200MHz bandwidth, 1M memory depth.
l          Powerful trigger function.
l          USB host, support flash memory card storage and USB interface system upgrade.
l          Ultrathin design, handy volume, easily portable.

* Oscilloscope Function
l          Bandwidth 60MHz-200MHz.
l          Each channel record length up to 1M.
l          Real time sampling rate up to 1GSa/s.
l          Powerful trigger function.
l          More than 20 kinds of automatic measurement function.

* Logic Analyzer Function
l          16 channels divided into 2 groups which is able to setup threshold level individually.
l          Real time sampling rate up to 500MSa/s.
l          Powerful trigger function: edge, duration, pulse width, code-type, queen, repeat.


 5. Specification


Oscilloscope Specification
Horizontal
Model
MSO5062D
MSO5102D
MSO5202D
Bandwidth
60MHz
100MHz
200MHz
Sampling Rate Range
Max. 1GS/s
Waveform Interpolation
( sin x) /x
Memory Depth (Sample Points)
Single-channel: maximum 1M; Dual-channel: maximum 512K (4K, 16K, 40K optional)
SEC/DIV Range
8ns/div-40s/div (stepping in a sequence: 2,4,8)
Sampling Rate and Delay Time Accuracy
±50ppm in any ≥1ms time intervals
Delta Time Measurement Accuracy (full bandwidth)

Single, "sampling" mode
± (1 sampling interval + 100ppm × readings + 0.6 ns)
> 16 times above average
± (1 sampling interval + 100ppm × readings + 0.4 ns)
Sampling interval = SEC/DIV÷200
Vertical
A/D Converter
8-bit resolution, each channel sampled simultaneously
VOLTS/DIV Range
2mV/div ~ 5V/div at input BNC
Position Range
±400mV (2mV/div ~20mV/div)
±2V (50mV/div ~200mV/div)
±40V (500mV/div ~2V/div)
±50V (5V/div)
Optional Analog Bandwidth Limit (typical)
20MHz
Low Frequency Response (-3db)
≤10Hz at output BNC
Rising Time at output BNC (typical)
60MHz
100MHz
200MHz
≤ 5.8ns
<3.5ns
<1.8ns
Vertical Gain Accuracy
±3% for sample or average acquisition mode, 5V/div to 10mV/div;
±4% for sample or average acquisition mode, 5mV/div to 2mV/div
DC Measurement Accuracy
Average Acquisition Mode
Measuring type: 16 zero vertical position waveform average .
Accuracy: ± (3%× reading+ 0.1div+ 1 mV), applicable to 10 mV/div or above units.
Measuring type: 16 non-zero vertical position waveform average.
Accuracy: ± [3%× (readings+ vertical position)+1%×vertical position+0.2div].
For the setting from 2mV/div to 200mV/div, +2mV; for 200mV/div to 5V/div, +50mV.
Voltage Measurement Repeatability
Average Acquisition Mode
In the same settings and environmental conditions, acquisition ≥ the voltage increment between any two groups average of 16 above waveforms : ± (3% × readings + 0.05 div)
Trigger
Trigger Sensitivity (Edge Trigger Type)
Coupling
Sensitivity
DC
Source
60MHz
100MHz
200MHz
CH1
CH2
1div from DC to 10MHz, 1.5div from 10MHz to Full
1.5div from 10MHz to 100MHz, 2div from 100MHz to Full
EXT
200mV from DC to 100MHz
200mV from DC to 100MHz, 350mV from 100MHz to 200MHz
EXT/5
1V from DC to 100MHz
1V from DC to 100MHz, 1.75V from 100MHz to 200MHz
AC
Attenuates signals below 10Hz
HF Reject
Attenuates signals when above 80kHz
LF Reject
The same as DC coupling limit when frequency above 150kHz; Attenuates signals when below 150kHz.
Trigger Level Range
Source
Range
CH1, CH2
±8 divisions from center of screen
EXT
±1.2V
EXT/5
±6V
Trigger Level Accuracy, typical (Accuracy is for signals having rise and fall time ≥ 20ns)
Source
Accuracy
CH1, CH2
±(0.2div × V/div) (within ±4 divisions from center of screen)
EXT
±(6% of setting+40mV)
EXT/5
±(6% of setting+200mV)
Set Trigger Level to 50% (typical)
For the input signals ≥ 50Hz
Video Trigger Type
Source
Range

CH1, CH2
The amplitude of 2 points peak-peak
EXT
400mV
EXT/5
2V
Signal Format , Field Rate and Video Trigger Type Any field or any line support NTSC PAL and SECAM

Holdoff Range
100ns-10s

Pulse Width Trigger
Mode
When <, >, =, or ≠ trigger; positive or negative pulses.
Trigger Point
: Triggers when pulse falling edge over trigger level.
≠: If the pulse narrower than the appointed width, the trigger point is the falling edge; or triggers when the pulse duration longer than the width setting time.
< : Triggers when the pulse duration less than the width setting time.
>(Also called overtime trigger): Triggers when pulse is greater than width setting.
Range
20ns ~10s
Slope Trigger
mode
When <, >, =, or ≠ trigger; positive or negative slopes.
Trigger Point
: Triggers when waveform slope is equal to slope setting.
≠: Triggers when waveform slope is not equal to slope setting.
<: Triggers when waveform slope is less than slope setting.
>: Triggers when waveform slope is greater than slope setting.
Range
20ns-10s
Overtime Trigger
From the rising or falling edge; Setup time: 20-10 s
Alternative Trigger
CH1
Internal trigger: edge, pulse, video, or slop
CH2
Internal trigger: edge, pulse, video, or slop
Trigger Frequency Counter
Readout Resolution
6bit
Accuracy (typical)
±30ppm (Including all of the frequency reference error and ±1 calculation error)
Frequency Range
AC coupling, from minimum 4Hz to specified bandwidth
Source
"Pulse width" or "edge trigger" mode: all available trigger source
"Frequency counter" is always measuring the trigger source, even when oscilloscope acquisition paused because of the operation state’s changing, or when a single acquisition finished.
The “pulse width" trigger mode: the oscilloscope calculates the pulses whose window having effective amplitude, which measure at 1s and meet trigger condition. For example, if the PWM pulse line is set to < mode, and width is correspondingly set to smaller time, then the narrow pulse among them is the one to be calculated.
"Edge trigger" mode: the oscilloscope calculates all the edge with sufficient amplitude and correct polarity.
"Video trigger" mode: "frequency counter" doesn't work.
Acquisition
Mode
Sample, Peak value detection and Average
SINGLE SEQ
Acquisition Mode
Acquisition Stop Time

Sample, peak value detect
All communications start to single acquisition simultaneously

Average
All communications  start to N times acquisition simultaneously, and N could be 4, 8, 16, 32, 64 or 128
Input
Input Coupling
DC, AC or GND
Input Impedance, DC Coupling
1MΩ±2% for 20pF±3 pF
Probe Attenuation
1X, 10X
Support Probe Attenuation Coefficients

1X, 10X, 100X, 1000X
Max. Input Voltage
Overvoltage Type
Max. Voltage
CAT I and CAT II
Installation type: 300VRMS(10×)
CAT III
150VRMS(1×)
Installation type : Take 20 dB/decade as slope, from 100kHz above begins to decline to ≥ 3MHz *, the AC peak value is 13V. For the non-sine waveforms, the peak value must less than 450V. Above 300V the offset duration should be less than 100ms. RMS signal level (including all the DC component delete by the AC coupling) must be limited to 300V. If beyond these values, it may damage the device.
Measurement
Cursors
The difference between voltage cursors V; the difference between time cursors T; 1/T calculated by Hz.
Automatic(32)
Frequency, Period, Mean, Pk-Pk, Cycli RMS, Minimum, Maximum, Rise time, Fall Time, +Pulse Width, -Pulse Width, Delay1-2Rise, Delay1-2Fall, +Duty, -Duty, Vbase, Vtop, Vmid, Vamp, Overshoot, Preshoot, Preiod Mean, Preiod RMS, FOVShoot, RPREShoot, BWIDTH、FRF、FFR、LRR、LRF、LFR、LFF
General
Display
Type
7” TFT, 64K true color LCD
Resolution
800x480 dots
Contrast
16 gears with the progress bar to show adjustment
Probe Compensator Output
Output Voltage (typical)
About 5Vpp input  ≥ 1 M Ω load
Frequency (typical)
1kHz
Power Supply
Voltage
100-120VACRMS(±10%),45Hz to 440Hz, CAT
120-240VACRMS(±10%),45Hz to 66Hz, CAT
Power
< 30W
Fuse
2A, T rating, 250V
Environment
Temperature
Working: 32 to 122 (0 to 50)
Not working: -40 to 159.8 (-40 to +71)
Cooling Type
Convection
Humidity
+ 104 or below (+ 40 or below) : 90% relative humidity
+ 106 to 122 (+ 40 to 50) : 60% relative humidity
Sea Level Height
Working and Not working
3,000m (10,000 foot)

Random Vibration
50 Hz to 500 Hz: 0.31 g RMS, each axial: 10 minutes

Not working
5 Hz to 500 Hz: 2.46 g RMS, each axial: 10 minutes
Mechanical Shock
Working
50g, 11ms, half-sine wave
Mechanical
Dimension
Length
313mm
Height
142mm
Thickness
108mm
Weight
Not including the weight of package and accessories
2.08Kg
Length
395mm
Width
410mm
Height
275mm
Gross Weight
Including all accessories
about 3.2kg
Logic Analyzer Specification
Sampled Channels
16 ( divided into 2 groups)
Max. Input Impedance
200K (C=10p)
Input Voltage Range
-60V~60V
Logic Threshold Range
-8V~8V
Max. Sample Rate
500MHz
Compatible Input
TTL, CMOS, ECL
Sample Depth
512KSample
Cursors
The difference between voltage cursors V; the difference between time cursors T; 1/T calculated by Hz.
Measurement
Period and Frequency
Record Position
RefA
RefB
Trigger
Edge
D0-D15 select slope (rising or falling edge)
Pulse Width
D0-D15 select pulse polarity (positive or negative pulse), trigger when (=, ≠, >, <), trigger pulse width
Code-type
D0-D15 select code-type (H, L, X)
Duration
D0-D15 select persist time and trigger when (data terminate, data start, and data delay)
Queue
D0-D15 select specific data index (0-3) and code-type (H, L, X)
Repeat
D0-D15 select code-type (H, L, X) and repeat times
















6. Software

 Operating system: Windows 7, Windows NT, Windows 2000, Windows XP, VISTA.



Hiç yorum yok:

Yorum Gönder